Basic Info.

Model NO.
U1GC350-G
Gas Source
Gas
Certification
CE
Power
>200kW
Standard
Standard
Genset Model
U1gc350-G
Gas Type
Natural Gas/Biogas/LPG/APG
Rated Voltage
400/230V
Transport Package
Plastic Membrane & Carton Box
Specification
4200*1700*2250
Origin
China
HS Code
8502200000
Production Capacity
100PCS/Year

Product Description

Genset working condition:
 

Applied gas: Natural Gas
Acceptable working conditions:

  • Ambient temperature: -10ºC ~+40ºC
  • Relative humidity: <90%, at 20ºC.
  • Altitude: ≤500m
  • Acceptable fuel gas pressure: 2~15kPa.
  • CH4 content: ≥70%
  • Gas low heat value (LHV): ≥19MJ/Nm³. If LHV <19MJ/Nm³, gas engine power output and electrical efficiency will decrease.
  • Gas characteristics: Gas must not contain free condensation water or free materials. Impurities should be ≤5μm.
  • H2S content: ≤100ppm
  • NH3 content: ≤50ppm
  • Silicon content: ≤5 mg/Nm³
  • Impurities content: ≤30mg/Nm³; size ≤5μm
  • Water content: ≤40g/Nm³, no free water.

Note:
If the applied gas is not Natural Gas, please contact customer service for specific operating requirements.
H2S will cause corrosion to engine components. It's better to control it below 130ppm if possible. However 200ppm is also acceptable.
Silicon can appear in engine lubricant oil. High silicon concentrations in the engine oil can cause heavily wear and tear on engine components. Engine oil must be assessed during CHP operation and oil type must be decided according to such oil assessment.


Gas Genset Specification:
 

Gas Generator Data
Genset Model U1GC350-G
Continuous Power 350kW/438kVA
Output Type 3 Phases 4 Wires
Voltage Output 400/230V
Power Factor 0.8 Lagging
Frequency (Hz) 50
Rated Speed (RPM) 1500
Steady-state Voltage Regulating Rate ≤±1.5%
Voltage Recovery Time (s) ≤1
Voltage Fluctuation Rate ≤1%
Frequency Recovery Time (s) ≤7
Frequency Fluctuation Rate ≤1%
 
Gas Engine Data
Engine Model K19N-G3
Engine Output (kWm) 388
Gas Type Natural Gas/Biogas
Type 4 Cycle, In-line, 6 Cylinder
Displacement 19L
Aspiration Turbocharged & Aftercooled
Bore*Stroke (mm) 159*159
Compression Ratio 11:1
NOx Emission 500mg/m³ NOx
Oil Consumption <0.2g/kW.h
Brake Thermal Efficiency Max 38%
Thermal Efficiency ~45%
LHV ≥15MJ/m³(400BTU/ft³)
MN ≥75
Cooling System 2 Pump 2 Loop
Ambient Temperature -25~45ºC
Spark Plug Life ≥4000h
Maintenance Interval 1000h
Wet Weight 2100kg
Dimension 2060*1075*1910mm
 
Alternator Data
Alternator Model TAL-A47-B
Continuous Power 455kVA/364kW
Rated Voltage (V) 400/230V, AC three phases
Excitation System Brushless, Self-excited
Frequency (Hz) 50
Efficiency 94.5%
Voltage Regulation ±1%
Insulation Class Class H
Protection Class IP 23
 
Controller ComAp/Deepsea
High-Efficiency Natural Gas/Biogas/LPG/APG 350kw Gas Generator Set for Farms, Industrial Park, Oil Field High-Efficiency Natural Gas/Biogas/LPG/APG 350kw Gas Generator Set for Farms, Industrial Park, Oil Field
 
Delivery time:
Within 40 days after receiving deposit.
Payment
T/T, 30% paid as deposit before production, 70% paid as balance paid before the shipment.
Warranty
We shall provide a warranty of 6000 running hours or 12 months from B/L date (whichever comes first), covering all manufacturing defects. We replace damaged parts caused by manufacturing faults or defected parts/materials, but excluding consumables parts and damageable parts due to customer's incorrect man-made operation. After expiration, we still provide technical and spare parts support with cost for maintenance.
Training and commissioning service
Free training can be provided in the factory by our gas power generation engineers. The training focuses on gas genset application, operation, and maintenance.
We can also send engineers to Customer's genset location site to do gas genset commissioning. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier