| Customization: | Available |
|---|---|
| Container Size: | 6058*2438*2591 (mm) |
| Weight: | 28t |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| DC Side | |
| Cell Type | LFP314Ah |
| PACK Configuration | 48.23kWh/1P48S |
| Battery System | 2170.3kWh/9P240S |
| DC Voltage Range | 672~864Vdc |
| PACK Ingress Rating | IP65 |
| Rated DC Voltage | 768V |
| Max.Charge/Discharge Rate | 0.5P |
| Max.Depth of Discharge | 100%(25 ± 2 ºC) |
| AC Side | |
| Rated Output Power | 1000kW |
| Max. Output Power | 1100kW |
| THDi | <3% |
| DC Ratio | <0.5%Ipn |
| AC Voltage Range | ±15% |
| Grid Type | 3W+PE/3W+N+PE |
| Rated AC Voltage | 230/400V |
| Nominal Frequency | 50/60 Hz |
| Power Factor | 0.99/ -1 ~ +1 |
| General | |
| Max. Round Trip Efficiency | ≥88% |
| Cycle Life | ≥8,000 times |
| Communication | Modbus TCP/IP, RS485 |
| Ingress Rating | IP55 |
| Cooling | Liquid cooling+Forced air cooling |
| Operating Temperature | -25ºC~55ºC(Derate after 45ºC) |
| Humidity | 5-95%RH, non-condensing |
| Noise | ≤80dB |
| Altitude | 4,000m (derating above 2,000m) |
| Fire Safety | Aerosol system(pack level and container level), Water spray system |
| Dimensions (W*D*H) | 6058*2438*2591 (mm) |
| Weight | 28T |
| Compliance | UN38.3, IEC62477, IEC61000, IEC62619, IEC63056, UL9540A, EN50549 |
![]() |
Liquid -Cooled Pack :
|
| DC-side Parameters | |
| Rated DC power (kW) | 125 |
|
Number of routes |
1 |
| Maximum input current (A) | 203 |
| Voltage range (V) | 680-950Vdc |
| Voltage limiting | Support |
| Current limiting | Support |
![]() |
POC cabinet is mainly divided into three parts: AC collection, auxiliary distribution, and energy management system (EMS).
1. AC Output and Grid Connection: The AC output side of PCS cabinet in the system is connected externally through the AC frame circuit breaker in the distribution cabinet; the container is connected to the power grid through the distribution cabinet.
2.Core parameters: the output specification is AC400V/50 (60) Hz, supporting three-phase four-wire system to connect to the low-voltage power supply network.
3.System configuration: AC pooling system is equipped with main switch and surge protector.
4.EMS function (integrated in the container) Responsible for container system data collection, monitoring, information uploading and instruction receiving; Realising communication interface with third party systems. |
![]() |
![]() |
![]() |
EMS Platform can monitor of PCS,BMS,air conditioning in real time.It can adapt charge and discharge strategies to achieve energy peak and valley arbitrage.Reducing customer electricity costs. EMS series products adopting an integrated architecture design, the system is suitable for user-side ESS, microgrid and PV-plus ESS and more. It ensures that the system operates optimally at all times, maximizing overall benefits and shortening ROI